Skip to main content

POLLING_INTERVAL - UEM Manager configuration option

Description

The POLLING_INTERVAL option specifies the frequency with which the UEM Server will check to see if an event's inactive date and time has elapsed; if so, the monitored state of the event is set to inactive.

If the inactive date and time has not elapsed, and the event is to remain active, UEM also checks for new occurrences of the specified event whenever the polling interval expires.

Usage

Method

Syntax

IBM i

HP NonStop

UNIX

Windows

z/OS

Command Line, Short Form

n/a

Command Line, Long Form

-polling_int seconds

Environment Variable

UEMPOLLINGINT=seconds

Configuration File Keyword

polling_int seconds

Value

seconds is the frequency (in seconds) for checking an event's inactive date and time.

Default

If this option is not used, the UEM Server configuration sets a default value of 30 seconds.